The Problem:

A customer of Tripar had been buying the Reduced Airflow IC Box, but discovered that it did not meet the maximum airflow requirements of a state specification. In this case this was the Florida Building Code, which prescribes 2 CFM max airflow at a negative pressure of 75 Pascals. Since then, similar airflow restrictionshave been imposed in many jurisdictions.

The Solution:

Tripar’s technical specialists analyzed the problem. They saw that the integral junction box used on these IC boxes was already gasketed and had knockouts of the “press-back” type that also did not contain screwdriver slots, meaning that the leakage was elsewhere.

Analysis showed excess airflow coming from two places:

-Joints within the box itself were overlapping, but there remained infinitesimal gaps over the length of the seams.

-The plaster frame was riveted to the IC Box both on the top and on two long edges, but the interface between the two was insufficient.

Tripar’s engineers attacked both sources of excess airflow by:

-Applying a caulking* to all interior joints of the IC box

-Applying a gasket* to the perimeter of the underside of the plaster frame where it contacted the riveted IC box.

Samples were submitted to the customer, which easily passed the prescribed airflow test.

The Result:

Tripar has successfully promoted and sold thousands of such IC boxes and plaster frames to multiple clients, coining the term “Ultra-Airtight”, indicating that they meet extremely stringent airflow requirements.

Tripar had airflow tests performed on the Ultra-Airtight I.C.Boxes by an independent and certified lab and passed with flying colors, obtaining airflow rates of under 0.2 cfm (10% of the 2 cfm permissible! see test report: http://lighting.triparinc.com/wp-content/uploads/2017/10/Tripar-I.C.Box-Air-Leakage-Report.pdf)

To read more about the Ultra Airtight I.C.Boxes please see the new product bulletin: http://lighting.triparinc.com/wp-content/uploads/2017/10/UT-IC-box-product-bulletin-Oct-2017.pdfAT Close up

*Both products used are recognized under UL94; the Standard for Safety of Flammability of Plastic Materials for Parts in Devices and Appliances testing.